Radiation Sensors TopPage Radiation Sensors

NaI(Tl) scintillation detectors
Distributed by APACE Science Home

thin crystal ( integral ) type detectors
  detector
  model number
crystal dimensions housing dimensions
diameter thickness diameter thickness
4T1mP1.5
/A or /B )
25.4mm
( 1.00inch )
1.0mm
( 0.0394inch )
44.5mm
( 1.750inch )
114.3mm
( 4.50inch )
4T2mP1.5
/A or /B )
25.4mm
( 1.00inch )
2.00mm
( 0.0787inch )
44.5mm
( 1.750inch )
114.3mm
( 4.50inch )
4T3mP1.5
/A or /B )
25.4mm
( 1.00inch )
3.00mm
( 0.1181inch )
44.5mm
( 1.750inch )
114.3mm
( 4.50inch )
4T4mP1.5
/A or /B )
25.4mm
( 1.00inch )
4.00mm
( 0.1575inch )
44.5mm
( 1.750inch )
114.3mm
( 4.50inch )
4T5mP1.5
/A or /B )
25.4mm
( 1.00inch )
5.00mm
( 0.1969inch )
44.5mm
( 1.750inch )
114.3mm
( 4.50inch )
4T6mP1.5
/A or /B )
25.4mm
( 1.00inch )
6.00mm
( 0.2362inch )
44.5mm
( 1.750inch )
114.3mm
( 4.50inch )
thin crystal standard detector   /A : Aluminum window
  /B : Beryllium window
  please specify on ordering
 
6T1mP1.5
/A or /B )
38.1mm
( 1.50inch )
1.00mm
( 0.0394inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
6T2mP1.5
/A or /B )
38.1mm
( 1.50inch )
2.00mm
( 0.0787inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
6T3mP1.5
/A or /B )
38.1mm
( 1.50inch )
3.00mm
( 0.1181inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
6T4mP1.5
/A or /B )
38.1mm
( 1.50inch )
4.00mm
( 0.1575inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
6T5mP1.5
/A or /B )
38.1mm
( 1.50inch )
5.00mm
( 0.1969inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
6T6mP1.5
/A or /B )
38.1mm
( 1.50inch )
6.00mm
( 0.2362inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
thin crystal standard detector   /A : Aluminum window
  /B : Beryllium window
  please specify on ordering
 
7T1mP2
/A or /B )
44.5mm
( 1.75inch )
1.00mm
( 0.0394inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
7T2mP2
/A or /B )
44.5mm
( 1.75inch )
2.00mm
( 0.0787inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
7T3mP2
/A or /B )
44.5mm
( 1.75inch )
3.00mm
( 0.1181inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
7T4mP2
/A or /B )
44.5mm
( 1.75inch )
4.00mm
( 0.1575inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
7T5mP2
/A or /B )
44.5mm
( 1.75inch )
5.00mm
( 0.1969inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
7T6mP2
/A or /B )
44.5mm
( 1.75inch )
6.00mm
( 0.2362inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
thin crystal standard detector   /A : Aluminum window
  /B : Beryllium window
  please specify on ordering
 
8T1mP2
/A or /B )
50.8mm
( 2.00inch )
1.00mm
( 0.0394inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
8T2mP2
/A or /B )
50.8mm
( 2.00inch )
2.00mm
( 0.0787inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
8T3mP2
/A or /B )
50.8mm
( 2.00inch )
3.00mm
( 0.1181inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
8T4mP2
/A or /B )
50.8mm
( 2.00inch )
4.00mm
( 0.1575inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
8T5mP2
/A or /B )
50.8mm
( 2.00inch )
5.00mm
( 0.1969inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
8T6mP2
/A or /B )
50.8mm
( 2.00inch )
6.00mm
( 0.2362inch )
58.8mm
( 2.312inch )
139.7mm
( 5.50inch )
thin crystal standard detector   /A : Aluminum window
  /B : Beryllium window
  please specify on ordering
 
General specifications / series nTxmP_
Housing
Spun aluminum: 1/32" (0.794mm) wall thickness
Radiation entrance window
Choose:
  * 0.005" (127µm) aluminum, 35mg/cm2
  * 0.005" (127µm) beryllium, 23mg/cm2
Resolution
PHRs on integral thin crystal detectors are guaranteed.   However, these resolutions are a function of incident gamma ray energy and typically range from 55% for the 5.9keV line of Fe-Mn-55, to 22% for the 22.5keV line of Cd-109.
Photomultiplier Tube
Unless specified, Radiation Sensors will select a suitable Photomultiplier tube.   A large selection of manufacturers and photomultiplier tube types are available upon request.
 
 



   Sorry, this page is still under the construction.
   Please wait a little while for complete information.


Radiation Sensors TopPage Radiation Sensors, LLC.
  NaI(Tl) scintillation detectors
   7762 Wall Triana Highway, Harvest, Alabama 35749    U.S.A.
   Phone# +1 - 256 - 325 - 2866 [325-atom]      Fax# +1 - 256 - 325 - 3291 [325-fax1]
   mail to:
radiationsensor@knology.net
   webSite: http://www.radiationsensors.com/
Local distributor in Japan
APACE Science
APACE Science, Inc.
  Mitomo-Bldg.#2 - 6F,   Ebisu-nishi 2-Chome,
  Shibuya-Ku, Tokyo 150-0021
Phone:
Fax: 
  +81 (0)3-3463-3204
  +81 (0)3-3463-3205


| page top | Radiation Sensor Home webSite | APACE Science TopPage |