Excellence in High Voltage Photo of KW series unit
AppliedKilovolts     KW series datasheet
KW1/250, KW2.5/100, KW5/50, KW10/25, KW15/16

HIGH POWER 250W HIGH VOLTAGE MODULES
  • 1kV, 2.5kV, 5kV, 10kV & 15kV
  • High efficiency
  • Off line, high frequency switch mode control
  • Internal control or externally programmable
  • Short circuit and flashover proof
  • 24 hour burn in
  • Low radiated magnetic field

Pin Connection & Safety Instructions

ELECTRICAL SPECIFICATION
unit type

polarity

output

ripple at full load

  KW1/250P

positive

50 volts to 1kV at 250mA

<0.25% peak to peak

  KW1/250N

negative

  KW2.5/100P

positive

100volts to 2.5kV at 100mA

<0.25% peak to peak

  KW2.5/100N

negative

  KW5/50P

positive

250volts to 5kV at 50mA

<0.25% peak to peak

  KW5/50N

negative

  KW10/25P

positive

500 volts to 10kV at 25mA

<0.25% peak to peak

  KW10/25N

negative

  KW15/16P

positive

750 volts to 15kV at 16mA

<0.25% peak to peak

  KW15/16N

negative


INPUT VOLTAGE: - 200 to 264V ac 50/60 Hz at 4.5A rms (110V option to special order).
OUTPUT VOLTAGE: - See separate table.
LINE REGULATION: - Less than 0.1% of maximum voltage for input changes of 10%.
LOAD REGULATION: - Less than 0.1% of maximum voltage for load changes from 10% to maximum.
OVERLOAD PROTECTION: - Flashover and short circuit proof. Current trip level variable by internal potentiometer,   External potentiometer or by analogue signal such that 0 to +10V sets 0 to maximum trip level.
TEMPERATURE CO-EFFICIENT: - 300ppm / °C or better.
CONTROL:
  • INTERNAL potentiometer.
  • EXTERNAL potentiometer or 10V analogue signal. (0 to +10V gives zero to maximum output, tolerance +2%). Input impedance > 100Kohm.
VOLTAGE MONITOR: - 0 to +10V represents zero to maximum voltage, source resistance 10 kohm.
CURRENT MONITOR: - 0 to +10V represents zero to maximum current, source resistance 10 kohm.
OPERATING TEMPERATURE: - 0°C to +45°C
STORAGE TEMPERATURE: - -35°C to +85°C
R.F.I.: - To EN55011.
SAFETY: - To EN61010-1.
MECHANICAL SPECIFICATION
SIZE: - All units 365mm x 220mm x 76mm.
OUTPUT: By 0.5 meter screened cable.   N.B. Reducing the cable length may increase the ripple voltage.
INPUT: Mains lead 2 meters long, control by D-type connector.


AppliedKilovolts Applied Kilovolts Ltd.     http://www.appliedkilovolts.com/
  38 - 40 Eastbrook Road, Portslade, Sussex,
  BN41 1PB, United Kingdom
  Phone: +44 (0) 1273   439 440        Fax: +44 (0) 1273   439 449
Local distributor in Japan
APACE Science
APACE Science, Inc.     http://www.apace-science.com/
  Mitomo-Bldg.#2 - 6F, Ebisu-nishi 2-Chome,
  2 - 8, Shibuya-Ku, Tokyo 150-0021
  Phone: +81 (0)3 - 3463 - 3204       Fax: +81 (0)3 - 3463 - 3205  

| standard modules | Page Top | Pin out | APACE Science Home |