HP Series power supply
AppliedKilovolts
HP series datasheet
HP1, HP2.5, HP5, HP10,
HP20, HP30 & HP60


PRECISION HIGH VOLTAGE MODULES
  • 1kV, 2.5kV,5kV, 10kV, 20kV, 30kV & 60kV
  • High Stability, Low Ripple
  • High frequency FET oscillator
  • Internal control or externally programmable
  • Short circuit and flashover proof
  • 24 hour burn in
  • Low radiated magnetic field

pin connection & instructions

ELECTRICAL SPECIFICATION
unit type polarity output ripple at full load
  HP1P positive 10 volts to 1kV at 10mA 10mV peak to peak
  HP1N negative
  HP2.5P positive 10 volts to 2.5kV at 4mA

10mV peak to peak
  HP2.5N negative
  HP5P positive 10volts to 5kV at 2mA 20mV peak to peak
  HP5N negative
  HP10P positive 20 volts to 10kV at 1mA 50mV peak to peak
  HP10N negative
  HP20P positive 50 volts to 20kV at 0.4mA 200mV peak to peak
  HP20N negative
  HP30P positive 100 volts to 30kV at 0.25mA 300mV peak to peak
  HP30N negative
  HP60P positive 200 volts to 60kV at 0.1mA 10V peak to peak
  HP60N negative

INPUT VOLTAGE: - 24 volt d.c. +10% at less than 1A. negative input terminal common to HV earth return.
OUTPUT VOLTAGE: - See table above.
LINE REGULATION: - Less than 10ppm of maximum voltage for input changes of 1 volt.
LOAD REGULATION: - Less than 10ppm for load changes from 100uA to maximum. (Measured at maximum voltage).
OVERLOAD PROTECTION: - Flashover and short circuit proof. Re-entrant current limit.
TEMPERATURE CO-EFFICIENT: - 25ppm / °C or better
(except HP60P & HP60N 150ppm / °C).
DRIFT: - Typically 0.01% per hour Measured at constant input voltage, 0.02% per 8 hours load current & ambient temperature after 1 hour warm up.
CONTROL:
  • INTERNAL potentiometer.
  • EXTERNAL potentiometer or 10V analogue signal.
    (0 to +10V gives zero to maximum output, tolerance +2%).
    Input impedance > 100Kohm.
READOUT: - Voltage monitor 0 to +10V represents zero to maximum output,  tolerance +2% (Source resistance 10 kohm).
CURRENT MONITOR: - Optional on all units. Note- simple current monitor includes the internally used feedback current.  Precision current monitor removes this current to give a true reading   (only available on HP10P & N, HP20P & N & HP30P & N).
OPERATING TEMPERATURE: - 0 °C to +50 °C
STORAGE TEMPERATURE: - -35 °C to +85 °C
R.F.I.: - Steel case for low radiated magnetic field.
SYNCHRONISATION: - Oscillator frequency can be locked to a suitable external frequency.
MECHANICAL SPECIFICATION
SIZE:
  • HP1, HP2.5 & HP5 -  148mm x 98mm x 47mm
  • HP10  -  200mm x 98mm x 47mm
  • HP20 & HP30  -  210mm x 120mm x 60mm
  • HP60 - 240mm x 140mm x 60mm                 
FIXINGS: HP1P & N, HP2.5P & N, HP5P & N, HP10P & N have M4 studs.  All other units have mounting holes.
OUTPUT: By 0.5 meter screened cable (HP20, HP30 & HP60
-- 1 meter).    N.B. Reducing the cable length may increase the ripple voltage.
INPUT CONNECTOR: Molex 10 pin, mating connector supplied.


AppliedKilovolts Applied Kilovolts Ltd.     http://www.appliedkilovolts.com/
  38 - 40 Eastbrook Road, Portslade, Sussex,
  BN41 1PB, United Kingdom
  Phone: +44 (0) 1273   439 440        Fax: +44 (0) 1273   439 449
Local distributor in Japan
APACE Science
APACE Science, Inc.     http://www.apace-science.com/
  Mitomo-Bldg.#2 - 6F, Ebisu-nishi 2-Chome,
  2 - 8, Shibuya-Ku, Tokyo 150-0021
  Phone: +81 (0)3 - 3463 - 3204       Fax: +81 (0)3 - 3463 - 3205  

| PageTop | standard modules | Pin Out | Current Monitor | APACE Science Home |